  1 new product sysmac cp-series cp1e cpu units cp1e-e @@ d @ -@ cp1e-n @@ d @ -@/ na20d @ -@ the cp1e package plcs: economical , easy to use, and efficient the e-type basic cpu units provide cost performance and easy application with only basic functionality. the n and na-types application cpu units support programmable terminal connection, position control, and inverter connection features ? programming, setting, and monitoring with cx-programmer. ? easy connection with computers using commercially available usb cables ? with e30/40, n30/40/60 or na20 cpu units, add i/o by connecting expansion i/o units. ? with e30/40, n30/40/60 or na20 cpu units, add analog i/o or temperature inputs by connecting expansion units. ? quick-response inputs ? input interrupts ? complete high-speed counter functionality. ? versatile pulse control for transistor output for n14/20/30/40/60 or na20 cpu units. ? pwm outputs for transistor output for n14/20/30/40/60 or na20 cpu units. ? built-in rs-232c port for n/na-type cpu units. ? mounting serial option boards or ethernet option board to n30/40/60 or na20 cpu units. ? built-in analog i/o, two inputs and one output, for na-type cpu units. cp1e-e20dr-a cp1e-n40dr-a
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 2 system configuration basic system configuration using an e-type cpu unit basic system configuration using an n/na-type cpu unit personal computer cp1e-e30dr-a cp1e-e40dr-a cp1e-e10d@-@ cp1e-e14dr-a cp1e-e20dr-a support software cx-programmer ibm pc/at or equivalent cp1e cpu unit expansion i/o units expansion units 20 or 40 i/o points 8 inputs 8 outputs 16 outputs 32 outputs up to 3 units can be connected cp1w-cn811 cp1e cpu unit expansion units and expansion i/o units i/o connecting cable when a two level layout is created by expansion and distance is required din track analog i/o analog inputs analog outputs temperature sensors compobus/s i/o link unit cp1e plcs are supported by cp1w-cif41 version 2.0 or higher. cp1e-n30d- cp1e-n40d- cp1e-n60d- cp1e-na20d- cp1e-n14d- cp1e-n20d- cp1e cpu unit expansion i/o units expansion units 20 or 40 i/o points 8 inputs 8 outputs 16 outputs 32 outputs analog i/o analog inputs analog outputs temperature sensors compobus/s i/o link unit up to 3 units can be connected din track cp1w-cn811 cp1e cpu unit expansion units and expansion i/o units i/o connecting cable personal computer ibm pc/at or equivalent built in rs-232c comm rs-232c option board cp1w-cif01 comm rs-422a/485 option board cp1w-cif11 cp1w-cif12 or or battery CP1W-BAT01 when a two level layout is created by expansion and distance is required (nt link/host link) general component (no-protocol mode) (modbus-rtu) cp-series plc or cj1m plc (serial plc link) host computer (host link) programmable terminal (pt) *the cp1w-dam01 lcd option board can not be used. inverter support software cx-programmer ethernet option board cp1w-cif41 ip address: subnet mask: comm err 10base-t 100base-tx
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 3 ordering information international standards ? the standards are abbreviated as follows: u: ul, u1: ul (class i division 2 products for hazardous locations), c: csa, uc: culu s, uc1: culus (class i division 2 products for hazardous locations), cu: cul, n: nk, l: lloyd, and ce: ec directives. ? contact your omron representative for further det ails and applicable condit ions for these standards. e-type cp1e cpu units (basic models) note: there are no accessories included wi th e-type cp1e cpu units. a battery (CP1W-BAT01) cannot be used. product name specifications external power supply (24 vdc) (a) current consumption (a) model standards power supply inputs outputs output type program capacity data memory capacity 5 v 24 v e-type cpu units with 10 i/o points 100 to 240 vac 64 relay 2k steps 2k words -- 0.08 0.04 cp1e-e10dr-a uc1, n, l, ce transistor (sinking) -- 0.11 -- cp1e-e10dt-a transistor (sourcing) -- 0.11 -- cp1e-e10dt1-a 24 vdc relay -- 0.08 0.04 cp1e-e10dr-d transistor (sinking) -- 0.11 -- cp1e-e10dt-d transistor (sourcing) -- 0.11 -- cp1e-e10dt1-d e-type cpu units with 14 i/o points 100 to 240 vac 8 6 relay 2k steps 2k words -- 0.16 0.07 cp1e-e14dr-a uc1, n, l, ce e-type cpu units with 20 i/o points 100 to 240 vac 12 8 relay 2k steps 2k words -- 0.17 0.08 cp1e-e20dr-a uc1, n, l, ce e-type cpu units with 30 i/o points 100 to 240 vac 18 12 relay 2k steps 2k words 0.30 0.17 0.07 cp1e-e30dr-a uc1, n, l, ce e-type cpu units with 40 i/o points 100 to 240 vac 24 16 relay 2k steps 2k words 0.30 0.17 0.09 cp1e-e40dr-a uc1, n, l, ce
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 4 n/na-type cp1e cpu unit s (application models) product name specifications external power supply (24 vdc) (a) current consumption (a) model standards power supply inputs outputs output type program capacity data memory capacity 5 v 24 v n-type cpu units with 14 i/o points 100 to 240 vac 86 relay 8k steps 8k words -- 0.17 0.07 cp1e-n14dr-a uc1, n, l, ce transistor (sinking) -- 0.22 0.02 cp1e-n14dt-a transistor (sourcing) -- 0.22 0.02 cp1e-n14dt1-a 24 vdc relay -- 0.17 0.07 cp1e-n14dr-d transistor (sinking) -- 0.22 0.02 cp1e-n14dt-d transistor (sourcing) -- 0.22 0.02 cp1e-n14dt1-d n-type cpu units with 20 i/o points 100 to 240 vac 12 8 relay 8k steps 8k words -- 0.18 0.08 cp1e-n20dr-a uc1, n, l, ce transistor (sinking) -- 0.23 0.02 cp1e-n20dt-a transistor (sourcing) -- 0.23 0.02 cp1e-n20dt1-a 24 vdc relay -- 0.18 0.08 cp1e-n20dr-d transistor (sinking) -- 0.23 0.02 cp1e-n20dt-d transistor (sourcing) -- 0.23 0.02 cp1e-n20dt1-d n-type cpu units with 30 i/o points 100 to 240 vac 18 12 relay 8k steps 8k words 0.30 0.21 0.07 cp1e-n30dr-a uc1, n, l, ce transistor (sinking) 0.30 0.27 0.02 cp1e-n30dt-a transistor (sourcing) 0.30 0.27 0.02 cp1e-n30dt1-a 24 vdc relay -- 0.21 0.07 cp1e-n30dr-d transistor (sinking) -- 0.27 0.02 cp1e-n30dt-d transistor (sourcing) -- 0.27 0.02 cp1e-n30dt1-d n-type cpu units with 40 i/o points 100 to 240 vac 24 16 relay 8k steps 8k words 0.30 0.21 0.09 cp1e-n40dr-a uc1, n, l, ce transistor (sinking) 0.30 0.31 0.02 cp1e-n40dt-a transistor (sourcing) 0.30 0.31 0.02 cp1e-n40dt1-a 24 vdc relay -- 0.21 0.09 cp1e-n40dr-d transistor (sinking) -- 0.31 0.02 cp1e-n40dt-d transistor (sourcing) -- 0.31 0.02 cp1e-n40dt1-d n-type cpu units with 60 i/o points 100 to 240 vac 36 24 relay 8k steps 8k words 0.30 0.21 0.13 cp1e-n60dr-a uc1, n, l, ce transistor (sinking) 0.30 0.31 0.02 cp1e-n60dt-a transistor (sourcing) 0.30 0.31 0.02 cp1e-n60dt1-a 24 vdc relay -- 0.21 0.13 cp1e-n60dr-d transistor (sinking) -- 0.31 0.02 cp1e-n60dt-d transistor (sourcing) -- 0.31 0.02 cp1e-n60dt1-d
cp1e-e @@ d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 5 note: there are no accessories included with n/na-t ype cp1e cpu units. rs-232c connectors for the built-in rs-232c port and the batte ry (CP1W-BAT01) are not included. na-type cpu units with 20 i/o points (built-in analog) 100 to 240 vac 12 (built-in analog inputs: 2) 8 (built-in analog outputs: 1) relay 8k steps 8k words 0.30 0.18 0.11 cp1e-na20dr-a uc1, n, l, ce 24 vdc transistor (sinking) -- 0.23 0.09 cp1e-na20dt-d transistor (sourcing) -- 0.23 0.09 cp1e-na20dt1-d battery set for n/na-type cp1e cpu units note: mount a battery to an n/na-type cpu unit if the data in the following areas must be backed up for power interruptions. ? dm area (d) (except backed up words in the dm area), holding area (h), counter completion flags (c), counter present values (c), auxiliary area (a), and clock function (use batteries within two years of manufacture.) CP1W-BAT01 -- product name specifications external power supply (24 vdc) (a) current consumption (a) model standards power supply inputs outputs output type program capacity data memory capacity 5 v 24 v
cp1e-e @@ d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 6 options (for cp1e n30/40/ 60 or na20 cpu units) the options cannot be used for cp1e n 14/20 cpu units and all e-type cpu units. note: it is not possible to use a cp-series ethernet option board vers ion 1.0 (cp1w-cif41), lcd option board (cp1w-dam01), or memory card (cp1w-me05m) with a cp1e cpu unit. programming devices note: 1. the e20, e30, e40, n20, n30 and n40 cpu units ar e supported by cx-programmer version 8.2 or higher. the e10, e14, n14, n60, and na20 cpu units are supported by cx-programme r version 9.03 or higher. when micro plc edition cx-programmer is used, you need version 9.03 or higher. 2. the cx-one and cx-one lite cannot be simu ltaneously installed on the same computer. * 1 multi licenses are available for t he cx-one (3, 10, 30 or 50 licenses). * 2 the cx-one is also available on cd (cxone-al @@ c-v4). the following tables lists the support so ftware that can be installed from cx-one note: for details, refer to the cx-one catalog (cat. no. r134). product name specifications model standards rs-232c option board one rs-232c option board can be mounted to the option board slot. for cp1e n30/40/60 or na20 cpu units only. one rs-232c connector is included. cp1w-cif01 uc1, n, l, ce rs-422a/485 option board one rs-422a/485 option board can be mounted to the option board slot. for cp1e n30/40/60 or na20 cpu units only. cp1w-cif11 rs-422a/485 isolated-type option board cp1w-cif12 uc1, n, l, ce ethernet option board one ethernet option board can be mounted to the option board slot. cp1e cpu units are supported by cp1w-cif41 version 2.0 or higher. for cp1e n30/40/60 or na20 cpu units only. when using cp1w-cif41, cx-programmer version 9.12 or higher is required. cp1w-cif41 uc1, n, l, ce product name specifications model standards number of licenses media fa integrated tool package cx-one lite ver.4. @ cx-one lite is a subset of the complete cx-one package that provides only the support software required for micro plc applications. cx-one lite runs on the following os. os: windows xp (service pack 3 or higher), vista or 7 note: except for windows xp 64-bit version. cx-one lite ver. 4. @ includes micro plc edition cx- programmer ver.9. @ . 1 license cd cxone-lt01c-v4 -- fa integrated tool package cx-one package ver. 4. @ cx-one is a comprehensive software package that integrates support software for omron plcs and components. cx- one runs on the following os. os: windows xp (service pack 3 or higher), vista or 7 note: except for windows xp 64-bit version. cx-one ver. 4. @ includes cx-programmer ver. 9. @ . 1 license *1 dvd *2 cxone-al01d-v4 -- support software in cx-one cx-one lite ver.4. @ cx-one ver.4. @ support software in cx-one cx-one lite ver.4. @ cx-one ver.4. @ micro plc edition cx-programmer ver.9. @ yes no cx-drive ver.2. @ yes yes cx-programmer ver.9. @ no yes cx-process tool ver.5. @ no yes cx-integrator ver.2. @ yes yes faceplate auto-builder for ns ver.3. @ no yes switch box utility ver.1. @ yes yes cx-designer ver.3. @ yes yes cx-protocol ver.1. @ no yes nv-designer ver.1. @ yes yes cx-simulator ver.1. @ yes yes cx-thermo ver.4. @ yes yes cx-position ver.2. @ no yes cx-configuratorfdt ver.1. @ yes yes cx-motion-ncf ver.1. @ no yes cx-flnet ver.1. @ no yes cx-motion-mch ver.2. @ no yes network configurator ver.3. @ yes yes cx-motion ver.2. @ no yes cx-server ver.4. @ yes yes
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 7 expansion i/o units and expansio n units (for cp1e e30/40, n 30/40/60, or na20 cpu units) cp1e e10/14/20 or n14/20 cpu units do not support expansion i/o units and expansion units. i/o connecting cable note: an i/o connecting cable (approx. 6 cm) for horizontal connection is provided with cp1w expansion i/o units and expansion units. unit type product name specifications current consumption (a) model standards inputs outputs output type 5 v 24 v cp1w expansion i/o units input unit 8- -- -0 . 0 1 8- - cp1w-8ed u, c, n, l, ce output units -- 8 relay 0.026 0.044 cp1w-8er transistor (sinking) 0.075 -- cp1w-8et transistor (sourcing) 0.075 -- cp1w-8et1 -- 16 relay 0.042 0.090 cp1w-16er n, l, ce transistor (sinking) 0.076 -- cp1w-16et transistor (sourcing) 0.076 -- cp1w-16et1 -- 32 relay 0.049 0.131 cp1w-32er n, l, ce transistor (sinking) 0.113 -- cp1w-32et transistor (sourcing) 0.113 -- cp1w-32et1 i/o units 12 8 relay 0.103 0.044 cp1w-20edr1 u, c, n, l, ce transistor (sinking) 0.130 -- cp1w-20edt transistor (sourcing) 0.130 -- cp1w-20edt1 24 16 relay 0.080 0.090 cp1w-40edr n, l, ce transistor (sinking) 0.160 -- cp1w-40edt transistor (sourcing) 0.160 -- cp1w-40edt1 cp1w expansion units analog input unit 4 analog inputs input range: 0 to 5 v, 1 to 5 v, 0 to 10 v, 10 v, 0 to 20 ma, or 4 to 20 ma. resolution: 1/6000 0.100 0.090 cp1w-ad041 uc1, n, l, ce analog output unit 2 analog outputs output range: 1 to 5 v, 0 to 10 v, 10 v, 0 to 20 ma, or 4 to 20 ma. resolution: 1/6000 0.040 0.095 cp1w-da021 uc1, ce 4 analog outputs output range: 1 to 5 v, 0 to 10 v, 10 v, 0 to 20 ma, or 4 to 20 ma. resolution: 1/6000 0.080 0.124 cp1w-da041 uc1, n, l, ce analog i/o unit 2 analog inputs and 1 analog output input range: 0 to 5 v, 1 to 5 v, 0 to 10 v, 10 v, 0 to 20 ma, or 4 to 20 ma. output range: 1 to 5 v, 0 to 10 v, 10 v, 0 to 20 ma, or 4 to 20 ma. resolution: 1/6000 0.083 0.110 cp1w-mad11 u, c, n, l, ce temperature sensor unit 2 temperature sensor inputs sensor type: thermocouple (j or k) 0.040 0.059 cp1w-ts001 4 temperature sensor inputs sensor type: thermocouple (j or k) 0.040 0.059 cp1w-ts002 2 temperature sensor inputs sensor type: platinum resistance thermometer (pt100 or jpt100) 0.054 0.073 cp1w-ts101 4 temperature sensor inputs sensor type: platinum resistance thermometer (pt100 or jpt100) 0.054 0.073 cp1w-ts102 compobus/s i/o link unit compobus/s slave 8 inputs and 8 outputs 0.029 -- cp1w-srt21 product name specifications model standards i/o connecting cable 80 cm (for cp1w expansion i/o units and expansion units) only one i/o connecting ca ble can be used in each plc. cp1w-cn811 uc1, n, l, ce
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 8 general specifications * 1 total of 110 mm with mounting brackets. * 2 excluding cables. * 3 use the external power supply to power input devices. do not use it to drive output devices. * 4 this is the rated value for the maximum sys tem configuration. use the following formula to calculate power consumption for cpu units with dc power. formula: dc power consumpti on = (5v current consumption ? 5 v/70% (internal power efficien cy) + 24v current consumption) ? 1.1(current fluctuation factor) the above calculation results show that a dc power supply with a greater capacity is required. type ac power supply models dc power supply models model cp1e- @@@ d @ -a cp1e- @@@ d @ -d enclosure mounted in a panel dimensions (h d w) cpu unit with 10 i/o points (cp1e-e10d @ - @ ): 90mm * 1 85mm * 2 66 mm cpu unit with 14 or 20 i/o points (cp1e- @ 14d @ - @ / @ 20d @ - @ ): 90mm * 1 85mm * 2 86 mm cpu unit with 30 i/o points (cp1e- @ 30d @ - @ ): 90mm * 1 85mm * 2 130 mm cpu unit with 40 i/o points (cp1e- @ 40d @ - @ ): 90mm * 1 85mm * 2 150 mm cpu unit with 60 i/o points (cp1e-n60d @ - @ ): 90mm * 1 85mm * 2 195 mm cpu unit with 20 i/o points and built-in analog (cp1e-na20d @ - @ ): 90mm * 1 85mm * 2 130 mm weight cpu unit with 10 i/o points (cp1e-e10d @ - @ ): 300g max. cpu unit with 14 i/o points (cp1e- @ 14d @ - @ ): 360g max. cpu unit with 20 i/o points (cp1e- @ 20d @ - @ ): 370g max. cpu unit with 30 i/o points (cp1e- @ 30d @ - @ ): 600g max. cpu unit with 40 i/o points (cp1e- @ 40d @ - @ ): 660g max. cpu unit with 60 i/o points (cp1e-n60d @ - @ ): 850g max. cpu unit with 20 i/o points and built-in analog (cp1e-na20d @ - @ ): 680g max. electrical specifications supply voltage 100 to 240 vac 50/60 hz 24 vdc operating voltage range 85 to 264 vac 20.4 to 26.4 vdc power consumption 15 va/100 vac max. 25 va/240 vac max. (cp1e-e10d @ -a/ @ 14d @ -a/ @ 20d @ -a) 9 w max. (cp1e-e10d @ -d) 13 w max. (cp1e-n14d @ -d/n20d @ -d) 50 va/100 vac max. 70 va/240 vac max. (cp1e-na20d @ -a/ @ 30d @ -a/ @ 40d @ -a/n60d @ -a) 20 w max. (cp1e-na20d @ -d/n30d @ -d/n40d @ -d/n60d @ -d) * 4 inrush current 120 vac, 20 a for 8 ms max. for cold start at room temperature 240 vac, 40 a for 8 ms max. for cold start at room temperature 24 vdc, 30 a for 20 ms max. for cold start at room temperature external power supply * 3 not provided. (cp1e-e10d @ -a/ @ 14d @ -a/ @ 20d @ -a) 24 vdc, 300 ma (cp1e-na20d @ -a/ @ 30d @ -a/ @ 40d @ -a/n60d @ -a) not provided insulation resistance 20 m min. (at 500 vdc) between the external ac terminals and gr terminals except between dc primary current and dc secondary current dielectric strength 2,300 vac 50/60hz for 1 min between ac external and gr terminals leakage current: 5 ma max. except between dc primary current and dc secondary current power off detection time 10 ms min. 2 ms min. application environment ambient operating temperature 0 to 55 c ambient humidity 10% to 90% atmosphere no corrosive gas. ambient storage temperature -20 to 75 c (excluding battery) altitude 2,000 m max. pollution degree 2 or less: conforms to jis b3502 and iec 61131-2. noise resistance 2 kv on power supply line (conforms to iec61000-4-4.) overvoltage category category ii: conforms to jis b3502 and iec 61131-2. emc immunity level zone b vibration resistance conforms to jis 60068-2-6. 5 to 8.4 hz with 3.5-mm amplitude, 8.4 to 150 hz acceleration of 9.8 m/s 2 for 100 min in x, y, and z directions (10 sweeps of 10 min each = 100 min total) shock resistance conforms to jis 60068-2-27. 147 m/s 2 , 3 times in x, y, and z directions terminal block fixed (not removable) terminal screw size m3 applicable standards conforms to ec directive grounding method ground to 100 or less.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 9 performance specifications item cp1e- @@ d @ - @ cp1e-n @@ d @ - @ cp1e-na @@ d @ - @ program capacity 2 k steps (8 kbytes) including the symbol table, comments, and program indices of the cx-programmer 8 k steps (32 kbytes) including the symbol table, comments, and program indices of the cx-programmer control method stored program method i/o control method cyclic scan with immediate refreshing program language ladder diagram instructions approximately 200 processing speed overhead processing time 0.4 ms instruction execution times basic instructions (ld): 1.19 s min. special instructions (mov): 7.9 s min. number of cp1w-series expansion units connected cp1e-e10d @ - @ / @ 14d @ - @ / @ 20d @ - @ : none cp1e- @ 30d @ - @ / @ 40d @ - @ /n60d @ - @ /na20d @ - @ : 3 units maximum number of i/o points cp1e-e10d @ - @ : 10 cp1e- @ 14d @ - @ : 14 cp1e- @ 20d @ - @ : 20 cp1e- @ 30d @ - @ : 150 (30 built in, 40 3 expansion) cp1e- @ 40d @ - @ : 160 (40 built in, 40 3 expansion) cp1e-n60d @ - @ : 180 (60 built in, 40 3 expansion) cp1e-na20d @ - @ : 140 (20 built in, 40 3 expansion) built-in i/o cp1e-e10d @ - @ : 10 (6 inputs, 4 outputs) cp1e- @ 14d @ - @ : 14 (8 inputs, 6 outputs) cp1e- @ 20d @ - @ : 20 (12 inputs, 8 outputs) cp1e- @ 30d @ - @ : 30 (18 inputs, 12 outputs) cp1e- @ 40d @ - @ : 40 (24 inputs, 16 outputs) cp1e-n60d @ - @ : 60 (36 inputs, 24 outputs) cp1e-na20d @ - @ : 20 (12 inputs, 8 outputs) built-in input functions high-speed counters high-speed counter mode/ maximum frequency incremental pulse inputs 10 khz: 6 counters 5 counters (only for 10 i/o points) up/down inputs 10 khz: 2 counters pulse + direction inputs 10 khz: 2 counters differential phase inputs (4x) 5 khz: 2 counters incremental pulse inputs 100 khz: 2 counters,10 khz: 4 counters up/down inputs 100 khz: 1 counters,10 khz: 1 counters pulse + direction inputs 100 khz: 2 counters differential phase inputs (4x) 50 khz: 1 counter, 5 khz: 1 counter counting mode linear mode ring mode count value 32 bits counter reset modes phase z and software reset (excluding increment pulse input) software reset control method target matching range comparison input interrupts 6 inputs (4 inputs only for 10 i/o points) interrupt input pulse width: 50 s min. quick-response inputs 6 inputs (4 inputs only for 10 i/o points) input pulse width: 50 s min. normal input input constants delays can be set in the plc setup (0 to 32 ms, default: 8 ms). set values: 0, 1, 2, 4, 8, 16, or 32 ms built-in output functions pulse outputs (models with transistor outputs only) pulse output method and output frequency pulse output function not included pulse + direction mode 1 hz to 100 khz: 2 outputs output mode continuous mode (for speed control) independent mode (for position control) number of output pulses relative coordinates: 0000 0000 to 7fff ffff hex (0 to 2147483647) absolute coordinates: 8000 0000 to 7fff ffff hex (-2147483647 to 2147483647) acceleration/ deceleration curves trapezoidal acceleration and deceleration (cannot perform s-curve acceleration and deceleration.) changing svs during instruction execution only target position can be changed. origin searches included pulse outputs (models with transistor outputs only) frequency pwm output function not included 2.0 to 6,553.5 hz (in increments of 0.1 hz) with 1 output or 2 hz to 32,000 hz (in increments of 1 hz) with 1 output duty factor 0.0% to 100.0% (in increments of 0.1%) accuracy: +1%/-0% at 2 hz to 10,000 hz and +5%/-0% at 10,000 hz to 32,000 khz output mode continuous mode built-in analog analog input analog function not included setting range: 0 to 6,000 (2 channels only for na-type) analog output setting range: 0 to 6,000 (1 channels only for na-type) analog adjusters 2 adjusters (setting range: 0 to 255)
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 10 item cp1e-e @@d @ - @ cp1e-n @@ d @ - @ cp1e-na @@d @ - @ communications b-type peripheral usb port conforming to usb 2.0 b type connector transmission distance 5 m max. built-in rs-232c port no built-in rs-232c port interface: conforms to eia rs-232c. communications method half duplex synchronization start-stop baud rate 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps transmission distance 15 m max. supported protocol ? host link ? 1:n nt link ? no-protocol mode ? serial plc links (master, slave) ? modbus-rtu easy master serial option port option board cannot be mounted. 1 port (option board can be mounted only to n30/40/ 60 and na20 cpu units.) mountable option boards ? one rs-232c port: cp1w-cif01 ? one rs-422a/485 port (not isolated): cp1w-cif11 ? one rs-422a/485 port (isolated): cp1w-cif12 ? one ethernet port: cp1w-cif41 communications method depends on option board. synchronization depends on option board. baud rate 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 kbps compatible protocols ? host link ? 1:n nt link ? no-protocol mode ? serial plc links (master, slave) ? modbus-rtu easy master number of tasks 17 ? one cyclic execution task ? one scheduled interrupt task (always interrupt task 1) ? six input interrupt tasks (interrupt tasks 2 to 7) ? sixteen high-speed counter interrupt tasks (interrupt tasks 1 to 16) maximum subroutine number 128 maximum jump number 128 scheduled interrupt tasks 1 interrupt task clock clock function not included. the time of error occurrence displays 01-01-01 01:01:01 sunday included. accuracy (monthly deviation): -4.5 min to -0.5 min at ambient temperature of 55 o c, -2.0 min to +2.0 min at ambient temperature of 25 o c, -2.5 min to +1.5 min at ambient temperature of 0 o c memory backup built-in eeprom ladder programs and parameters are automatically saved to built-in eeprom a section of the data memory area can be saved to the built-in eeprom. battery backup with CP1W-BAT01 battery (sold separately) battery cannot be mounted. CP1W-BAT01 can be used. maximum battery service life: 5 years backup time guaranteed value (ambient temperature: 55 o c): 13,000 hours (approx. 1.5 years) effective value (ambient temperature: 25 o c): 43,000 hours (approx. 5 years) cio area input bits 1,600 bits (100 words): cio 0.00 to cio 99.15 (cio 00 to cio 99) output bits 1,600 bits (100 words): cio 100.00 to cio 199.15 (cio 100 to cio 199) serial plc link words 1,440 bits (90 words): cio 200.00 to cio 289.15 (words cio 200 to cio 289) work area (w) 1,600 bits (100 words): w0.00 to w99.15 (w0 to w99) holding area (h) 800 bits (50 words): h0.00 to h49.15 (h0 to h49) bits in this area maintain their on/off status when operating mode is changed. auxiliary area (a) read-only: 7,168 bits (448 words) a0 to a447 read/write: 4,896 bits (306 words) in words a448 to a753 temporary relay area (tr) (tr area) 16 bits: tr0 to tr15 timer area (t) 256 timer numbers (t0 to t255 (separate from counters)) counter area (c) 256 counter numbers (c0 to c255 (separate from timers)) data memory area (d) 2 kwords: d0 to d2047 of these, 1,500 words can be saved to the backup memory (built-in eeprom) using settings in the auxiliary area. 8 kwords: d0 to d8191 of these, 7,000 words can be saved to the backup memory (built-in eep-rom) using settings in the auxiliary area operating modes program mode: program execution is stopped. preparations can be executed prior to program execution in this mode. monitor mode: programs are executed. some operations, such as online editing, and c hanges to present values in i/o memory, are enabled in this mode. run mode: programs are executed. this is the normal operating mode.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 11 function specifications function function description cycle time management minimum cycle time makes the cycle time consistent. monitoring the cycle time monitors the cycle time. cpu unit built-in functions inputs high-speed counter inputs high-speed pulse inputs high-speed pulses from devices such as a rotary encoder are counted. the counted values are stored in the auxiliary area. interrupt tasks can be executed when tar get is reached or by range comparison. input pulse frequency measurement the frequency of pulses input by the prv instruction is measured. interrupt inputs relevant interrupt tasks are ex ecuted during the cycle when the cpu unit built-in inputs turn on or turn off. quick-response inputs inputs can be read without being affected by cycle time. use the quick-response inputs to read signals shorter than the cycle time. normal inputs i/o refreshing cyclic refreshing the cpu unit?s built-in i/ o are cyclically refreshed. immediate refreshing i/o refreshing by immediate refreshing instructions input response times input constants can be set for basic i/o units. the response time can be increased to reduce the effects of chattering and noise at input contacts. the response time can be decreased to enable detecting shorter input pulses. outputs pulse outputs (models with transistor outputs only) pulse control a pulse signal is output and positioning or speed control is performed with a servo driver that accepts a pulse input. continuous mode for speed control or independent mode for position control can be used. there are functions for changing to positioni ng during speed control and for changing the target value during positioning. origin positioning origin searches and origin returns pwm outputs (models with transistor outputs only) pulses for which the duty ratio (ratio betw een on time and off time during one pulse cycle) can be set are output. normal outputs load off function all of the outputs on the cpu unit?s i/o ca n be turned off when an error occurs in run or monitor mode. built-in analog analog input convert analog signal into digital value range from 0 to 6,000. analog output convert digital value range from 0 to 6,000 into analog signal. expansion i/o units and expansion units functions supported by both expansion i/o unit and expansion unit i/o refreshing cyclic refreshing the expansion i/o units and expans ion units are cyclically refreshed. refreshing by iorf i/o refreshing by iorf instruction load off function all of the outputs on expansion i/o units and expansion units are turned off (0000 hex) when an error occurs in run or monitor mode. expansion i/o units input response times the response time can be increased to reduce the effects of chattering and noise at input contacts. the response time can be decreased to enable detecting shorter input pulses. expansion units unit error detection errors in expansion units are detected. the cpu unit is notified that the expansion unit stopped due to an error. memory management functions holding i/o memory when changing operating modes the status of i/o memory can be held when the operating mode is changed. the forced-set/reset status can be held when the operating mode is changed. automatic backup to the backup memory (built-in eeprom) automatic backup of ladder programs and parameter area to the backup memory (built-in eeprom) communic ations peripheral usb port peripheral bus (toolbus) for communications with programming device (cx-programmer). serial port (n/na-type only) -- host link (sysway) communications host link commands can be sent from a pt or a computer to read/write i/o memory, and perform other operations for plc. no-protocol communications i/o instructions for communications ports (txd/rxd instructions) can be used for data transfer with peripheral devices such as bar code readers. nt link communications i/o memory in the plc can be allocated and di rectly linked to various pt functions, including status control areas, status notific ation areas, touch switches, lamps, memory tables, and other objects. serial plc links up to ten words per unit can be shared by up to nine cpu units, including one polling unit and eight polled units. note: programmable terminal (pt) cannot be connected. modbus-rtu easy master function modbus-rtu commands are sent by the mo dbus-rtu master func tion. modbus slaves, such as inverters, can be easily c ontrolled with serial communications. interrupt scheduled interrupts tasks can be executed at a specified in terval (1.0 ms min., unit: 0.1 ms). interrupt inputs interrupt tasks are processed when the built-in input turns on or off. high-speed counter interrupts this function counts input pulses with the cpu unit?s built-in high-speed counter and executes an interrupt task when the count reache s the preset value or falls within a preset range (target value or zone comparison).
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 12 function function description power supply management memory protection holding area data, dm area data, counter completion flags, and counter present values are held even when power is turned off. this function can be used only with an n/na-type cpu unit and only when the battery set (sold separately) is mounted. number of power interruptions counter the number of times power has been interrupted is counted. debugging online editing the program can be changed during operation in monitor mode or program mode. force-set/reset specified bits can be set or reset. differentiate monitoring on/off changes in specified bits can be monitored. storing the stop position at errors the location and task number where execution stopped for a program error is recorded. program check the programs can be checked for items such as no end instruction and fals/fal errors at startup. self-diagnosis and restoration error log details and the time of occurrence of error codes predefined by the cpu unit are stored. cpu error detection cpu unit wdt errors are detected. user-defined failure diagnosis errors can be generated fo r user-specified conditions: non-fatal errors (fal) and fatal errors (fals). load off function the built-in outputs, expansion i/o unit outputs, and expansion unit outputs are turned off. non-fatal error detection system fal error detection (user-defined non-fatal error) this function generates a non-fatal (fal) erro r when the user-defined conditions are met in program. backup memory error detection this function detects when data in the back up memory (built-in eeprom) that stores the ladder program is corrupted. plc setup error detection this function detects setting errors in the plc setup. option board errors this function detects when the option board is malfunctioning or disconnected. battery error detection (n/na-type cpu units only) this function detects when the battery volt age is low or the battery is disconnected. note: this function is valid only when a battery is mounted and the do not detect battery error check box is cleared in the plc setup. built-in analog error this function detects when a built-in analog i/o error occurs and stops the operation of built- in analog i/o. fatal error detection memory error detection this function detects errors that occur in memory of the cpu unit. i/o bus error detection this function detects errors that occur during data transfer between the cpu unit and another unit. too many i/o points error detection this function detects when more than the maximum number of cp1w expansion i/o units and expansion units are connected to the plc. program error detection this function detects when there is an error in the program. see the following for details. instruction processing error detection this function detects an error when the giv en data value is invalid when executing an instruction, or execution of inst ruction between tasks was attempted. indirect dm addressing bcd error this function detects an error when an indirect dm address in bcd mode is not bcd. illegal area access error detection this function detects an error when an attemp t is made to access an illegal area with an instruction operand. no end error detection this function detects an error when there is no end instruction at the end of the program. task error detection the execution condition for an interrupt task was met but there is no interrupt task with the specified number. overflow error detection this function detects an error when too many differentiated instructions are entered or deleted during online editing (131,072 times or more). invalid instruction error detection this function detects an error when an attempt is made to execute an instruction that is not defined in the system. user program area overflow error detection this function detects an error when instruction data is stored after the last address in user program area. cycle time exceeded error detection this function monitors the cycle time (10 to 1,000 ms) and stops the operation when the set value is exceeded. system fals error detection (user-defined fatal error) this function generates a fatal (fals) error when the user-defined conditions are met in program. maintenance automatic online connection via network this function enables automatically connecting to the plc online when the cx-programmer is directly connected by a serial connection (peripheral usb port or serial port). security functions read protection using password this function protects user memory. read protection: set a password using the cx-programmer. overwrite protection is not provided. write protection from fins commands this function prohibits writing by usin g fins commands sent over the network.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 13 internal memory in the cpu units cpu unit memory backup structure the internal memory in the cpu unit consists of built-in ram and built-in eeprom. t he built-in ram is used as execution memory and the built- in eeprom is used as backup memory. precautions for correct use create a system and write the ladder programs so that problems will not occur in the system if the data in these area may be un stable. ? data in areas such as the dm area (d), holding area (h), the counter present values (c) and th e status of counter completion fl ags (c), which is retained by the battery, may be unstable when the power supply is turned off (except for the dm area that are retained by th e built-in eep- rom using the auxilliary area bit.) ? the error log, and clock data (n/na-type cpu unit only) in the auxiliary area will become unstabl e. other words and bits in the auxiliary area will be cleared to their default values. the built-in capacitor?s backup time varies with the ambient temperat ure as shown in the following graph. cpu unit built-in eeprom built-in ram backup memory user program area (backup) plc setup plc setup dm area dm area user program area i/o memory areas data is retained even if the power supply is interrupted for longer than the backup time of the built-in capacitor. execution memory automatic backup read at startup automatic backup read at startup backup using bit in auxiliary area dm area data read at startup if a CP1W-BAT01 battery (sold separately) is mounted to an n/na-type cpu unit, which is normally backed up by a built-in capacitor, data will be backed up by the battery. area where data is backed up even if the power supply is interrupted for longer than the back-up time of the built-in capacitor. area where data is cleared if the power supply is interrupted for longer than the back-up time of the built-in capacitor. backup time of built-in capacitor 50 hours 40 hours 25 hours 20 hours 9 hours 7 hours cp1e e-type cpu unit cp1e n/na-type cpu unit ambient temperature 25 40 60
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 14 i/o memory areas data can be read and written to i/o memory fr om the ladder programs. i/o memory consis ts of an area for i/o with external devic es, user areas, and system areas. i/o memory areas name no. of bits word addresses remarks cio area input bits 1,600 bits (100 words) cio 0 to cio 99 for na-type, cio90, cio91 is occupied by analog input 0, 1. output bits 1,600 bits (100 words) cio 100 to cio 19 9 for na-type, cio190 is occupied by analog output 0. serial plc link words 1,440 bits (90 words) cio 200 to cio 289 -- work area (w) 1,600 bits (100 words) w0 to w99 -- holding area (h) 800 bits (50 words) h0 to h49 data in this area is retained during power interruptions if a battery set (sold separately) is mounted to an n/na-type cpu unit. data memory area (d) e-type cpu unit 2k words d0 to d2047 data in specified words of the dm area can be retained in the built-in eeprom in the backup memory by using a bit in the auxiliary area. applicable words: d0 to d1499 (one word can be specified at a time.) n/na-type cpu unit 8k words d0 to d8191 data in specified words of the dm area can be retained in the built-in eeprom in the backup memory by using a bit in the auxiliary area. applicable words: d0 to d6999 (one word can be specified at a time.) timer area (t) present values 256 t0 to t255 -- timer completion flags 256 -- counter area (c) present values 256 c0 to c255 data in this area is retained during power interruptions if a battery set (sold separately) is mounted to an n/na-type cpu unit. counter completion flags 256 -- auxiliary area (a) read only 7168 bits (448 words) a0 to a447 data in this area is retained during power interruptions if a battery set (sold separately) is mounted to an n/na-type cpu unit. read-write 4,896 bits (306 words) a448 to a753 input bits (starting from cio 0) user areas holding area (h) dm area (d) timer area (t) counter area (c) output bits (starting from cio 100) work area (w) system areas auxiliary area (a) condition flags clock pulses
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 15 backing up and restoring dm area data the contents of the dm area (d) will becom e unstable if the power supply is interrupt ed for longer than the backup time of the built-in capacitor (50 hours for an e-type cpu unit, 40 hours for an n/na-type cpu unit without a battery). the contents of the specified words in the dm area data can be bac ked up from ram to the built-in eeprom backup memory during o peration by turning on a bit in the auxiliary area. the number of dm area words to back up is specified in the number of ch of dm for ba ckup box in the plc setup. if the restore d0- from backup memory check box is selected in the plc setup, the backup data will automatically be restored to ram when the power is turned back on so that data is not lost even if power is interrupted. conditions for executing backup specified words starting from d0 in the ram can be saved to the built-in eeprom backup memory by turning on a751.15. (these words are called the dm backup words and the data is called the dm backup data.) a751.15 (dm backup save start bit) can be used in any operating mode (run, monitor, or program mode). words that can be backed up ? e-type cp1e cpu units: d0 to d1499 ? n/na-type cp1e cpu units: d0 to d6999 number of words to back up the number of words to back up starting from d0 is set in the number of ch of dm for backup box in the startup data read area in the plc setup. restoring dm backup data to ram when power is turned on the dm backup data can be restored to ram when power is turned on by selecting the restore d0- from backup memory check box in the startup data read area in the plc setup. the dm backup data will be read from the backup memory even if the clear retained memory area (hr/dm/cnt) check box is selected in the plc setup. d0 d(n-1) built-in ram cp1e cpu unit a751.15 (dm backup save start bit) turned on dm area (d) data backed up built-in eeprom backup memory dm backup data specified number of words specify the number of words starting from d0 in the number of ch of dm for backup box in the startup data read area in plc setup. dm backup data is restored to the ram when power supply is turned on again if the restore d0- from backup memory check box is selected in the startup data read area in the plc setup. data restored
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 16 built-in inputs terminal arrangements input terminal arrangement for cpu unit with 10 i/o points ac power supply models dc power supply models input terminal arrangement for cpu unit with 14 i/o points ac power supply models dc power supply models input terminal arrangement for cpu unit with 20 i/o points ac power supply models dc power supply models input terminal arrangement for cpu unit with 30 i/o points ac power supply models dc power supply models cio 0 l1 l2/n com 01 03 05 00 02 04 nc + ? com 01 03 05 00 02 04 nc cio 0 cio 0 l1 l2/n com 01 03 05 07 nc nc 00 02 04 06 nc nc nc + ? com 01 03 05 07 nc nc 00 02 04 06 nc nc nc cio 0 cio 0 l1 l2/n com 01 03 05 07 09 11 00 02 04 06 08 10 nc cio 0 +? com 01 03 05 07 09 11 00 02 04 06 08 10 nc l1 l2/n com nc 01 03 05 07 09 11 00 02 04 06 08 10 01 03 05 00 02 04 cio 0 cio 1 +? com nc nc 01 03 05 07 09 11 00 02 04 06 08 10 01 03 05 00 02 04 cio 0 cio 1
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 17 input terminal arrangement fo r cpu unit with 40 i/o points ac power supply models dc power supply models input terminal arrangement fo r cpu unit with 60 i/o points ac power supply models dc power supply models input terminal arrangement for cpu unit with 20 i/o points and built-in analog ac power supply models dc power supply models l1 l2/n com 01 03 05 00 02 04 07 09 11 06 08 10 01 03 05 00 02 04 07 09 11 06 08 10 cio 0 cio 1 +? com nc 01 03 05 00 02 04 07 09 11 06 08 10 01 03 05 00 02 04 07 09 11 06 08 10 cio 0 cio 1 l1 l2/n com 01 03 05 00 02 04 07 09 11 06 08 10 01 03 05 00 02 04 07 09 11 06 08 10 01 03 05 00 02 04 07 09 11 06 08 10 cio 0 cio 1 cio 2 cio 0 cio 1 cio 2 01 03 05 07 09 11 04 08 01 03 05 07 09 11 00 00 00 02 04 06 08 10 01 03 05 07 09 11 02 04 06 08 10 nc + ? 02 com 06 10 l1 l2/n com com1 01 03 05 07 09 11 00 02 04 06 08 10 i in0 ag i in1 vin0 com0 vin1 cio 0 cio 90 cio 91 cio 0 cio 90 cio 91 + - com com1 01 03 05 07 09 11 00 nc 02 04 06 08 10 i in0 ag i in1 vin0 com0 vin1
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 18 allocating built-in inputs to functions input terminals are allocated functions by setting parameters in the plc setup. set the plc setup so that each terminal is used for only one function. cpu unit with i/o points input terminal block settings in plc setup interrupt input setting on built-in input tab page high-speed counter 0 to 3 setting on built-in input tab page origin search settings on pulse output 0/1 tab page terminal block label terminal number normal interrupt quick single-phase (increment pulse input) two-phase (differential phase x4 or up/down) two-phase (pulse/ direction) cpu unit with 20 to 60 points cpu unit with 14 i/o points normal input input interrupt quick- response input 10 cio 0 00 normal input 0 -- -- counter 0, increment input counter 0, phase a or up input counter 0, pulse input -- -- 01 normal input 1 -- -- counter 1, increment input counter 0, phase b or down input counter 1, pulse input -- -- 02 normal input 2 interrupt input 2 quick-response input 2 counter 2, increment input counter 1, phase a or up input counter 0, direction -- -- 03 normal input 3 interrupt input 3 quick-response input 3 -- counter 1, phase b or down input counter 1, direction -- pulse 0, origin proximity input signal 04 normal input 4 interrupt input 4 quick-response input 4 counter 3, increment input counter 0, phase z or reset input counter 0, reset input -- -- 05 normal input 5 interrupt input 5 quick-response input 5 counter 4, increment input counter 1, phase z or reset input counter 1, reset input -- pulse 1, origin proximity input signal 14 06 normal input 6 interrupt input 6 quick-response input 6 counter 5, increment input -- -- pulse 0: origin input signal pulse 0, origin input signal 07 normal input 7 interrupt input 7 quick-response input 7 -- -- -- pulse 1: origin input signal pulse 1, origin input signal 20 08 normal input 8 -- -- -- -- -- -- -- 09 normal input 9 -- -- -- -- -- -- -- 10 normal input 10 -- -- -- -- -- pulse 0: origin proximity input signal -- 11 normal input 11 -- -- -- -- -- pulse 1: origin proximity input signal -- 30 cio 1 00 to 05 normal input 12 to17 -- -- -- -- -- -- -- 40 06 to 11 normal input 18 to 23 -- -- -- -- -- -- -- 60 cio 2 00 to 11 normal input 24 to 35 -- -- -- -- -- -- -- these functions ar e supported only by n/na-type cpu units with transistor outputs.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 19 built-in outputs terminal arrangements output terminal arrangement for cpu unit with 10 i/o points ac power supply model dc power supply model output terminal arrangement for cpu unit with 14 i/o points ac power supply model dc power supply model output terminal arrangement for cpu unit with 20 i/o points ac power supply model dc power supply model output terminal arrangement for cpu unit with 30 i/o points ac power supply model dc power supply model output terminal arrangement for cpu unit with 40 i/o points ac power supply model dc power supply model output terminal arrangement for cpu unit with 60 i/o points ac power supply model dc power supply model output terminal arrangement for cpu unit with 20 i/o points and built-in analog ac power supply model dc power supply model 00 01 02 03 com com nc com nc cio 100 00 01 02 03 com com nc com 04 05 nc nc comnc cio 100 00 01 02 03 com com nc com 04 05 07 06 comnc cio 100 00 01 02 04 05 07 00 03 06 02 01 03 + - com comcom com com cio 100 cio 101 00 01 02 04 05 07 00 03 06 02 01 03 nc nc com comcom com com cio 100 cio 101 +0001 07 02 03 04 06 00 01 com com 05 07 com 03 04 06 02 05 com com com- cio 100 cio 101 cio 100 cio 101 nc 00 01 07 02 03 04 06 00 01 com com 05 07 com 03 04 06 02 05 com com comnc cio 101 cio 100 cio 102 + 0001020405070002040507 comcom- com 03 com 06 com 01 03 com 06 00 com 02 01 04 03 05 com 07 06 cio 101 cio 100 cio 102 nc 00 01 02 04 05 07 00 02 04 05 07 comcomnc com 03 com 06 com 01 03 com 06 00 com 02 01 04 03 05 com 07 06 cio 100 cio 190 00 01 02 04 05 07 nc 03 06 iout0 vout0 com0 + ? com comcom com nc cio 100 cio 190 02 01 04 05 07 nc iout0 00 com com com com nc nc nc 03 06 vout0 com0
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 20 allocating built-in output terminals to functions output terminals are allocated functions by setting parameters in the plc setup. set the plc setup so that each terminal is use d for only one function. cpu unit with i/o points output terminal block other than those shown right when a pulse output instruction (sped, acc, pls2, or org) is executed setting in plc setup when the pwm instruction is executed origin search setting on pulse output 0/1 tab page terminal block label terminal number normal output fixed duty ratio pulse output variable duty ratio pulse output pulse + direction use pwm output 10 cio 100 00 normal output 0 pulse output 0 (pulse) -- -- 01 normal output 1 pulse output 1 (pulse) -- pwm output 0 02 normal output 2 pulse output 0 (direction) -- -- 03 normal output 3 pulse output 1 (direction) -- -- 14 04 normal output 4 -- pulse 0: error counter reset output -- 05 normal output 5 -- pulse 1: error counter reset output -- 20 06 normal output 6 -- -- -- 07 normal output 7 -- -- -- 30 cio 101 00 to 03 normal output 8 to 11 -- -- -- 40 04 to 07 normal output 12 to 15 -- -- -- 60 cio 102 00 to 07 normal output 16 to 23 -- -- -- these functions are supported only by n/na-type cpu units with transistor outputs.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 21 i/o specifications for cpu units input specifications * 1 the bits that can be used depend on the model of cpu unit. * 2 the response time is the delay caused by hardware. the delay set in the plc se tup (0 to 32 ms, default: 8 ms) for a normal inpu t must be added to this value. item specification input type high-speed counter inputs or normal inputs high-speed counter inputs, interrupt input, quick-response inputs, or normal inputs normal inputs input bits cio 0.00 to cio 0.01 cio 0.02 to cio 0.07 * 1 cio 0.08 to cio 0.11, cio 1.00 to cio 1.11 and cio 2.00 to cio 2.11 * 1 input voltage 24 vdc, +10%, -15% applicable sensors 2-wire and 3-wire sensors input impedance 3.3 k 3.3 k 4.8 k input current 7.5 ma typical 7.5 ma typical 5 ma typical on voltage/current 3 ma min. at 17.0 vdc min. 3 ma min. at 17.0 vdc min. 3 ma min. at 14.4 vdc min. off voltage/current 1 ma max. at 5.0 vdc max. 1 ma max. at 5.0 vdc max. 1 ma max. at 5.0 vdc max. on response time * 2 e-type cpu unit: 50 s min. n/na-type cpu unit: 2.5 s min. 50 s max. 1 ms max. off response time * 2 e-type cpu unit: 50 s min. n/na-type cpu unit: 2.5 s min. 50 s max. 1 ms max. circuit configuration e-type cpu unit n/na-type cpu unit input 0.00 to 0.07 input 0.08 to 0.11, 1.00 to 1.11 input 0.00 to 0.01 input 0.02 to 0.07 inputs cio 0.08 to cio 0.11, cio 1.00 to cio 1.11 and cio 2.00 to cio 2.11 input indicator in in com 3.3k 910 1000pf internal circuits internal circuits in in com 4.8k 750 input indicator in in com 3.3k 4.3k 1000pf input indicator internal circuits in in com 910 1000pf 3.3k input indicator internal circuits in in com 750 4.8k internal circuits input indicator on off on off on off t 1 t 2 t 3 t 4 t 1 , t 2 , t 3 , t 4 : 2.5 s min. 90% 50% 10% 90% 50% 10% 90% 50% 10% 2.5 s min. 2.5 s min. 20.0 s min. 10.0 s min. up/down input mode differential phase mode pulse plus direction input mode, increment mode n/na-type: 0.00/0.01 n/na-type: 0.00/0.01 on off on off on off t 1 t 2 t 3 t 4 t 1 , t 2 , t 3 , t 4 : 50 s min. 90% 50% 10% 90% 50% 10% 90% 50% 10% 50 s min. 50 s min. 200 s min. 100 s min. e-type: 0.00 to 0.07 n/na-type: 0.02 to 0.07 e-type: 0.00 to 0.03 n/na-type: 0.02/0.03
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 22 output specifications output specifications for relay outputs estimating the serv ice life of relays under normal conditions, the service life of output contacts is as shown above. the service life of relays is as shown in the f ollowing diagram as a guideline relationship between continuous simultan eous on rate and ambient temperature there are restrictions on the power supply voltage and output load current imposed by the ambient temperature. make sure that t he power supply voltage and output load current are within the following ranges. note: the above restrictions apply to the relay output load current fr om the cpu unit even if expansion i/o units are not connected. item specification maximum switching capacity 250 vac/2 a (cos = 1) 2 a, 24 vdc (4 a/common) minimum switching capacity 5 vdc, 10 ma service life of relay electrical resistive load 200,000 operations (24 vdc) inductive load 70,000 operations (250 vac, cos = 0.4) mechanical 20,000,000 operations on delay 15 ms max. off response time 15 ms max. circuit configuration cp1e- @@ dr- @ cp1e-n14dr-d/cp1e-n20dr-d cp1e-n30dr-d cp1e-n40dr-d cp1e- @ 14dr-a/cp1e- @ 20dr-a/cp1e-n20dt @ - @ cp1e-na20dr-a cp1e-n60dr-d output indicator internal circuits com out out 250 vac, 2a, 24 vdc, 2 a max. 30-vdc/250-vac resistive load 125-vac resistive load 125 vac cos= 0.4 250 vac cos= 0.4/ 30 vdc, = 7ms contact current (a) life (x 10 4 ) 300 500 700 1000 200 100 50 70 30 20 5 7 3 2 10 0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10 1 50% 100% 55 ?c 45 0% power voltage 21.6 vdc power voltage 20.4 vdc ambient temperature 40 50% 0% 100 % 35 45 55?c power voltage 21.6 vdc power voltage 20.4 vdc ambient temperature 30 45 50 50% 100% 55 ?c 0% power voltage 21.6 vdc power voltage 20.4 vdc ambient temperature 50% 100% 55 ?c 50 0% ambient temperature 80% 100% 55 c 0% 50 ambient temperature 50% 100% 55 ?c 45 0% power voltage 21.6 vdc power voltage 20.4 vdc ambient temperature 40
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 23 output specifications for transist or outputs (sinking or sourcing) normal outputs note: do not connect a load to an output terminal or apply a voltage in excess of the maximum switching capacity. * 1 also do not exceed 0.9 a for the total for cio 100.00 to cio 100.03. (cio 100.00 to cio 100.03 is different common.) * 2 the bits that can be used depend on the model of cpu unit. pulse outputs (cio 10 0.00 and cio 100.01) note: 1. the load for the above values is assumed to be the resistanc e load, and does not take into account the impedance for the connec ting cable to the load. 2. due to distortions in pulse waveforms re sulting from connecting cable impedance, the pulse widths in actual operation may be sm aller than the values shown above. 3. the off and on refer to the output transistor. the output transistor is on at level ?l?. pwm output (cio 100.01) note: the off and on refer to the output transistor. the output transistor is on at level ?l?. item specification cio 100.00 and cio 100.01 cio 100.02 to cio 100.07, cio 101.00 to cio 101.07 and cio 102.00 to cio 102.07 * 2 maximum switching capacity 0.3 a/output, 0.9 a/common * 1 4.5 to 30 vdc cp1e-e10d @ - @ : 0.9 a/unit cp1e-n14d @ - @ : 1.5 a/unit cp1e-n20d @ - @ : 1.8 a/unit cp1e-n30d @ - @ : 2.7 a/unit cp1e-n40d @ - @ : 3.6 a/unit cp1e-n60d @ - @ : 5.4 a/unit cp1e-na20d @ - @ : 1.8 a/unit minimum switching capacity 1 ma 4.5 to 30 vdc leakage current 0.1ma max. residual voltage e-type cpu unit: 1.5 v max. n/na-type cpu unit: 0.6 v max. 1.5v max. on response time 0.1 ms max. 0.1 ms max. off response time e-type cpu unit: 1 ms max. n/na-type cpu unit: 0.1 ms max. 1 ms max. fuse not provided. circuit configuration n/na-type cpu unit: normal outputs cio 100.00 to cio 100.01 (sinking) n/na-type cpu unit: normal outputs cio 100.00 to cio 100.01 (sourcing) e-type cpu unit: normal outputs cio 100.00 to cio 100.03 (sinking) n/na-type cpu unit: normal outputs cio 100.02 to cio 102.07 (sinking) e-type cpu unit: normal outputs cio 100.01 to cio 100.03 (sourcing) n/na-type cpu unit: normal outputs cio 100.02 to cio 102.07 (sourcing) item specification maximum switching capacity 100 ma/4.5 to 26.4 vdc minimum switching capacity 7 ma/4.5 to 26.4 vdc maximum output frequency 100 khz output waveform item specification maximum switching capacity 30 ma/4.5 to 26.4 vdc maximum output frequency 32 khz pwm output accuracy for on duty +1%, .0%:10 khz output for on duty +5%, .0%: 0 to 32 khz output output waveform out out ~ com(?) l l internal circuits internal circuits 24 vdc, 4.5 to 30 vdc internal circuits out out l l com(+) internal circuits 24 vdc, 4.5 to 30 vdc ~ out out com(?) l l 24 vdc, 4.5 to 30 vdc internal circuits ~ out out com(+) l l 24 vdc, 4.5 to 30 vdc internal circuits ~ 4s min. 2s min. off 90 % on 10 % t on duty= 100 % t t on t on off on
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 24 built-in analog i/o (na-type cpu units) analog input specifications analog output specifications * in 0 to 20 ma mode, accuracy cannot be ensured at 0.2 ma or less. shared i/o specifications item voltage input current input number of inputs 2 inputs (allocat ed 2 words: cio 90 to cio 91.) input signal range 0 to 5 v, 1 to 5 v, 0 to 10 v, or -10 to 10 v 0 to 20 ma or 4 to 20 ma max. rated input 15 v 30 ma external input impedance 1 m min. approx. 250 resolution 1/6000 overall accuracy at 25c 0.3% full scale 0.4% full scale 0 to 55c 0.6% full scale 0.8% full scale a/d conversion data -10 to +10 v f448 to 0bb8 hex fs other ranges 0000 to 1770 hex fs averaging function supported (set for individual inputs in the plc setup.) open-circuit detection function supported (value when disconnected: 8000 hex) item voltage output current output number of outputs 1 output (allocated 1 word: cio 190.) output signal range 0 to 5 v, 1 to 5 v, 0 to 10 v, or -10 to 10 v 0 to 20 ma or 4 to 20 ma allowable external output load resistance 1 k min. 600 max. external input impedance 0.5 max. --- resolution 1/6000 overall accuracy at 25c 0.4% full scale * 0 to 55c 0.8% full scale * d/a conversion data -10 to +10 v f448 to 0bb8 hex fs other ranges 0000 to 1770 hex fs item specification conversion time 2 ms/point (6 ms total for 2 analog inputs and 1 analog output.) isolation method photocoupler isolation between analog i/o terminals and internal circuits. no isolation between analog i/o signals.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 25 specifications of expansion i/o units and expansion units expandable cpu units ? expansion i/o units and expansion units cannot be connected to e10/14/20 or n14/20 cpu units. ? a total of up to three expansion i/o units and expansion un its can be connected to an e30/40, n30/40/60 or na20 cpu unit. cp1e e10/14/20 or n14/20 cpu unit cp1e e30/40, n30/40/60 or na20 cpu unit connection methods connection cables for the expansion i/o unit s and expansion units are used to connect the units. the length can be extended by using a cp1w- cn811 i/o connection cable (length: 800 m). maximum number of i/o points for an expanded system restrictions on external power supply capacity the following restrictions apply when using the cpu unit?s external power supply. ac-power-supply e30/40, n 30/40/60 or na20 cpu unit the power supply capacity is restricted for ac-power-supply e30/40, n30/40/60 or na20 cp u units. it may not be possible to use the full 300 ma of the external power supply, though a cpu unit can co nnect any cp-series expansion i/o unit or expansion unit. the entire 300 ma from the external power supply can be us ed if expansion units and expansi on i/o units are not connected. refer to the cp1e cpu unit hardware manual (cat. no. w479) for details. ac-power-supply or dc-power-suppl y e10/14/20, n14/20 cpu unit there is no external power suppl y on ac-power-supply or dc-power-sup ply e10/14/20, n14/20 cpu units. cpu unit built-in i/o on cpu unit built-in analog total number of expansion i/o units and expansion units that can be connected number of inputs: 24 number of outputs: 16 total number of i/o points when three cp1w-40ed @ expansion i/o units are connected total number of inputs number of outputs ad da total number of inputs number of outputs cp1e-e10d @ - @ 10 6 4 none none not possible. 10 6 4 cp1e- @ 14d @ - @ 14 8 6 14 8 6 cp1e- @ 20d @ - @ 20 12 8 20 12 8 cp1e- @ 30d @ - @ 30 18 12 3 units maximum 150 90 60 cp1e- @ 40d @ - @ 40 24 16 160 96 64 cp1e-n60d @ - @ 60 36 24 180 108 72 cp1e-na20d @ - @ 20 12 8 2 1 140 84 56 cp-series expansion units and expansion i/o units cannot be connected. a total of up to three cp-series expansion i/o units and expansion units can be connected. ch nc nc nc nc nc nc com com com com com com com 03 06 01 03 06 00 02 04 06 08 10 00 01 02 04 05 07 00 02 04 05 07 00 02 04 06 08 10 01 03 05 07 09 11 01 03 05 07 09 11 in 40edr out ch ch ch ch exp ch ch ch 11100908070605 04 03020100 11100908070605 04 03020100 070605 04 03020100 070605 04 03020100 ch nc nc nc nc nc nc com com com com com com com 03 06 01 03 06 00 02 04 06 08 10 00 01 02 04 05 07 00 02 04 05 07 00 02 04 06 08 10 01 03 05 07 09 11 01 03 05 07 09 11 in 40edr out ch ch ch ch exp ch ch ch 1110090807 06 05 0403 0201 00 1110090807 06 05 0403 0201 00 07 06 05 0403 0201 00 07 06 05 0403 0201 00 ch nc nc nc nc nc nc com com com com com com com 03 06 01 03 06 00 02 04 06 08 10 00 01 02 04 05 07 00 02 04 05 07 00 02 04 06 08 10 01 03 05 07 09 11 01 03 05 07 09 11 in 40edr out ch ch ch ch exp ch ch ch 11100908070605040302 0100 11100908070605040302 0100 070605040302 0100 070605040302 0100
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 26 specifications of expansion i/o units input specifications (cp1w-40edr/40 edt/40edt1/20edr1/ 20edt/20edt1/8ed) note: do not apply voltage in excess of the rated voltage to the input terminal. * the response time is the hardware delay value. the delay set in the plc setup (0 to 32 ms, default: 8 ms) must be added to this value. for the cp1w-40edr/edt/edt1, a fixed value of 16 ms must be added. output specifications relay outputs (cp1w-40edr/32er/20edr1/16er/8er) note: 1. estimating the service life of relays the service life of output contacts is as shown in the following diagram. item specification input voltage 24 vdc +10%/-15% input impedance 4.7 k input current 5 ma typical on voltage 14.4 vdc min. off voltage 5.0 vdc max. on delay 1 ms max. * off delay 1 ms max. * circuit configuration item specification max. switching capacity 2 a, 250 vac (cos = 1), 2 a, 24 vdc (4 a/common) min. switching capacity 5 vdc, 10 ma service life of relay (see note.) electrical resistive load 150,000 operations (24 vdc) inductive load 100,000 operations (240 vac, cos = 0.4) mechanical 20,000,000 operations on delay 15 ms max. off delay 15 ms max. circuit configuration v in in com 4.7 k 750 input led internal circuits com out out output led internal circuits maximum 250 vac: 2 a 24 vdc: 2 a 300 200 100 50 30 20 5 3 2 10 0.1 0.2 0.3 0.5 0.7 1 235 life ( 10 4 ) contact current (a) 120 vac resistive load 24 vdc = 7 ms 120 vac cos = 0.4 240 vac cos = 0.4 24 vdc/240 vac resistive load switching rate: 1,800 operations/hou r
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 27 2. restrictions of cp1w-16er/32er limit the output load current to satisfy the following derating curve. 3. cp1w-32er?s maximum number of simult aneously on output points is 24 (75%). relation between number of on outputs and ambient temperature (cp1w-32er) 4. according to the ambient temperature, there are restrictions on power supply voltage and output load current for the cpu units connected with the expansion i/o units (cp1 w-8er/16er/20edr1/32er/40edr). use the plc in the range of the power supply voltage and output load current as show below. the ambient temperature is restricted for the power-supply cpu units (cp1e-n/na @@@@ - @ ). derating curve of the output load current for expansion i/o units (cp1w-8er/16er/20edr1/32er/40edr). connected to cp1e-n30dr-d connected to cp1e-n40dr-d connected to cp1e-n30dt @ -d connected to cp1e-n40dt @ -d connected to cp1e-n60dr-d/cp1e-n60dt @ -d connected to cp1e-na20dt @ -d connected to cp1e-na20dr-a 100 50 55 43 ambient temperature(?c) output load current(%) 0 ambient temperature (?c) 55 number of inputs on simultaneously (%) 75 0 50% 100% 55 c 45 35 0% power voltage: 21.6 vdc power voltage: 20.4 vdc ambient temperature 50% 100% 55 c 45 30 0% 50 power voltage: 21.6 vdc power voltage: 20.4 vdc ambient temperature 50% 100% 55 c 4535 0% power voltage: 21.6 vdc power voltage: 20.4 vdc ambient tem p erature 50% 100% 55 c 4535 0% power voltage: 21.6 vdc power voltage: 20.4 vdc ambient temperature 50% 100% 55 c 45 0% 40 power voltage: 21.6 vdc power voltage: 20.4 vdc ambient temperature 50% 100% 55 c 45 0% 40 power voltage: 21.6 vdc power voltage: 20.4 vdc ambient temperature 80% 100% 55 c 0% 50 ambient temperature
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 28 transistor outputs (sinking or sourcing) *1 if the ambient temperature is maintained below 50 c, up to 0.9 a/common can be used. *2 the fuse cannot be replaced by the user. replace the unit if the fuse breaks due to an short-circ uit or overcurrent. *3 do not connect a load to an output terminal or apply a voltage in excess of the maximum switching capacity. item specification cp1w-40edt cp1w-40edt1 cp1w-32et cp1w-32et1 cp1w-20edt cp1w-20edt1 cp1w-16et cp1w-16et1 cp1w-8et cp1w-8et1 max. switching capacity * 1 4.5 to 30 vdc 0.3 a/output 4.5 to 30 vdc 0.3 a/output 24 vdc +10%/-5% 0.3 a/output 4.5 to 30 vdc 0.3 a/output 4.5 to 30 vdc 0.3 a/output 0.9 a/common 3.6 a/unit 0.9 a/common 7.2 a/unit 0.9 a/common 1.8 a/unit 0.9 a/common 3.6 a/unit 0.9 a/common 1.8 a/unit leakage current 0.1 ma max. 0.1 ma max. 0.1 ma max. 0.1 ma max. 0.1 ma max. residual voltage 1.5 v max. 1.5 v max. 1.5 v max. 1.5 v max. 1.5 v max. on delay 0.1 ms max. 0.1 ms max. 0.1 ms. 0.1 ms max. 0.1 ms max. off delay 1 ms max. 24 vdc +10%/-5% 5 to 300 ma 1 ms max. 24 vdc +10%/-5% 5 to 300 ma 1 ms max. 24 vdc +10%/-5% 5 to 300 ma 1 ms max. 24 vdc +10%/-5% 5 to 300 ma 1 ms max. 24 vdc +10%/-5% 5 to 300 ma max. number of simultaneously on points of output 16 pts (100%) 24 pts (75%) 8 pts (100%) 16 pts (100%) 8 pts (100%) fuse * 2 1 fuse/common circuit configuration com (?) out out l l com (+) out out l l sinking outputs sourcing outputs output led output led internal circuits internal circuits 24 vdc/4.5 to 30 vdc 24 vdc/4.5 to 30 vdc 0.9 0.8 (a) 0 (c) 50 55 ambient tem p erature total current for common
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 29 specifications of expansion units analog input units analog output units model cp1w-ad041 item voltage input current input number of inputs 4 inputs (4 words allocated) input signal range 0 to 5 vdc, 1 to 5 vdc, 0 to 10 vdc, or ?10 to 10 vdc 0 to 20 ma or 4 to 20 ma max. rated input 15 v 30 ma external input impedance 1 m min. approx. 250 resolution 1/6000 (full scale) overall accuracy 25 c 0.3% full scale 0.4% full scale 0 to 55 c 0.6% full scale 0.8% full scale a/d conversion data 16-bit binary (4-digit hexadecimal) full scale for ?10 to 10 v: f448 to 0bb8 hex full scale for other ranges: 0000 to 1770 hex averaging function supported (set in output words n+1 and n+2.) open-circuit detection function supported conversion time 2 ms/point (8 ms/all points) isolation method photocoupler isolation between analog i/o terminals and inte rnal circuits. no isolati on between analog i/o signals. current consumption 5 vdc: 100 ma max.; 24 vdc: 90 ma max. model cp1w-da021/cp1w-da041 item voltage output current output analog output section number of outputs cp1w-da021: 2 outputs (2 words allocated) cp1w-da041: 4 outputs (4 words allocated) output signal range 1 to 5 vdc, 0 to 10 vdc, or ?10 to 10 vdc 0 to 20 ma or 4 to 20 ma external output allowable load resistance 2 k min. 350 max. external output impedance 0.5 max. --- resolution 1/6000 (full scale) overall accuracy 25 c 0.4% full scale 0 to 55 c 0.8% full scale d/a conversion data 16-bit binary (4-digit hexadecimal) full scale for ?10 to 10 v: f448 to 0bb8 hex full scale for other ranges: 0000 to 1770 hex conversion time cp1w-da021: 2 ms/point (4 ms/all points) cp1w-da041: 2 ms/point (8 ms/all points) isolation method photocoupler isolation between analog i/o terminals and inte rnal circuits. no isolation between analog i/o signals. current consumption cp1w-da021: 5 vdc: 40 ma max.; 24 vdc: 95 ma max. cp1w-da041: 5 vdc: 80 ma max.; 24 vdc: 124 ma max.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 30 analog i/o units temperature sensors units * accuracy for a k-type sensor at -100 c or less is 4c 1 digit max. the rotary switch is used to set the temperature range. compobus/s i/o link unit model cp1w-mad11 item voltage i/o current i/o analog input section number of inputs 2 inputs (2 words allocated) input signal range 0 to 5 vdc, 1 to 5 vdc, 0 to 10 vdc, or ? 10 to 10 vdc 0 to 20 ma or 4 to 20 ma max. rated input 15 v 30 ma external input impedance 1 m min. approx. 250 resolution 1/6000 (full scale) overall accuracy 25 c 0.3% full scale 0.4% full scale 0 to 55 c 0.6% full scale 0.8% full scale a/d conversion data 16-bit binary (4-digit hexadecimal) full scale for ? 10 to 10 v: f448 to 0bb8 hex full scale for other ranges: 0000 to 1770 hex averaging function supported (settable for individual inputs via dip switch) open-circuit detection function supported analog output section number of outputs 1 output (1 word allocated) output signal range 1 to 5 vdc, 0 to 10 vdc, or ? 10 to 10 vdc, 0 to 20 ma or 4 to 20 ma allowable external output load resistance 1 k min. 600 max. external output impedance 0.5 max. resolution 1/6000 (full scale) overall accuracy 25 c 0.4% full scale 0 to 55 c 0.8% full scale set data (d/a conversion) 16-bit binary (4-digit hexadecimal) full scale for ? 10 to 10 v: f448 to 0bb8 hex full scale for other ranges: 0000 to 1770 hex conversion time 2 ms/point (6 ms/all points) isolation method photocoupler isolation between analog i/ o terminals and internal circuits. no isolation between analog i/o signals. current consumption 5 vdc: 83 ma max., 24 vdc: 110 ma max. item cp1w-ts001 cp1w-ts002 cp1w-ts101 cp1w-ts102 temperature sensors thermocouples platinum resistance thermometer switchable between k and j, but same type must be used for all inputs. switchable between pt100 and jpt100, but same type must be used for all inputs. number of inputs 2424 allocated input words 2424 accuracy (the larger of 0.5% of converted value or 2 c) 1 digit max. * (the larger of 0.5% of converted value or 1 c) 1 digit max. conversion time 250 ms for 2 or 4 input points converted temperature data 16-bit binary data (4-digit hexadecimal) isolation photocouplers between all temperature input signals current consumption 5 vdc: 40 ma max., 24 vdc: 59 ma max. 5 vdc: 54 ma max., 24 vdc: 73 ma max. setting cp1w-ts001/ts002 cp1w-ts101/ts102 input type range ( c) range ( f) input type range ( c) range ( f) 0 k ? 200 to 1,300 ? 300 to 2,300 pt100 ? 200.0 to 650.0 ? 300.0 to 1,200.0 1 0.0 to 500.0 0.0 to 900.0 jpt100 ? 200.0 to 650.0 ? 300.0 to 1,200.0 2 j ? 100 to 850 ? 100 to 1,500 --- cannot be set. 3 0.0 to 400.0 0.0 to 750.0 --- 4 to f --- cannot be set. --- model number cp1w-srt21 master/slave compobus/s slave number of i/o points 8 input points, 8 output points number of words allocated in cpu unit i/o memory 1 input word, 1 output word node number setting set using the dip switch (set before turning on the cpu unit?s power supply.)
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 31 external interfaces the cp1e cpu units provide the following external interfaces. e10/14/20 or n14/20 cpu units note: terminal block (fixed) e30/40, n30/40/60 or na20 cpu units note: terminal block (fixed) serial communications port for n/na-type cpu units the serial communication port can be used for a cp1e n/na-type cpu unit. e-type n-type e-type n-type/na-type input terminal block output terminal block power supply input terminals input terminals output terminals ground terminal input indicators output indicators peripheral usb port analog adjusters operation indicators battery cover built-in rs-232c port built-in rs-232c communications status indicator input terminal block output terminal block power supply input terminals input terminals output terminals external power supply ground terminal input indicators output indicators peripheral usb port analog adjusters operation indicators expansion i/o unit connector serial option board slot built-in rs-232c communications status indicator battery cover built-in rs-232c port analog input terminal (na-type only) analog output terminals (na-type only) cp1e n30/40/60 or na20 cpu units cp1w-cif11/12 rs-422a/485 option board cp1w-cif01 rs-232c option board built-in rs-232c port cp1w-cif41 ethernet option board version 2.0 or higher ip address: subnet mask: comm err 10base-t 100base-tx optional serial communication board model number port maximum transmission distance connection method cp1w-cif01 one rs-232c port 15 m connector (d-sub, 9 pin female) cp1w-cif11 one rs-422a/485 port (not isolated) 50 m terminal block (using ferrules) cp1w-cif12 one rs-422a/485 port (isolated) 500 m terminal block (using ferrules) cp1w-cif41 one ethernet port 100 m connector (rj45, 8 pin modular)
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 32 built-in rs-232c port and cp1w -cif01 rs-232c option board cp1w-cif11/cif12 rs-422a/485 option board cp1w-cif41 ethernet option board version 2.0 or higher specifications fins communications se rvice specifications comm front back communications status indicator rs-232 connector cpu unit connector rs-232c connector pin abbr. signal name signal direction 1 fg frame ground -- 2 sd (txd) send data output 3 rd (rxd) receive data input 4 rs (rts) request to send output 5 cs (cts) clear to send input 6 5 v power supply -- 7 dr (dsr) data set ready input 8 er (dtr) data terminal ready output 9 sg (0 v) signal ground -- connector hood fg frame ground -- 5 6 1 9 note: do not use the 5-v power from pin 6 of the rs-232c port for anything but cj1w-cif11 rs -422a conversion adapter, nt-al001 rs-232c/rs-422a conversion adapter and nv3w-m @ 20l programmable terminal. the external device or the cpu unit may be damaged. comm front back communications status indicator dip switch for operation settings rs-422a/485 connector rda- rdb + sda- sdb + fg cpu unit connector rs-422a/485 terminal block rdb+ rda- sda- sdb+ fg tighten the terminal block screws to a torque of 0.28 nm. ip address: subnet mask: comm err 10base-t 100base-tx front rear label attach the label here to show ip address and subnet mask. ethernet connector used to connect the ethernet twisted-pair cable. led indicators display the operating status of the option board. cpu unit connector type 100/10base-tx (auto-mdix) support software cx-programmer version 9.12 or higher transfer media access method csma/cd modulation method baseband transmission paths star form baud rate 100 mbit/s (100base-tx) 10 mbit/s (10base-tx) ? half/full auto-negotiation for each port ? link speed auto-sensing for each port transmission media ? unshielded twisted-pair (udp) cable categories: 5, 5e ? shielded twisted- pair (stp) cable categories: 100 at 5, 5e ? unshielded twisted-pair (udp) cable categories: 3, 4, 5, 5e ? shielded twisted- pair (stp) cable categories: 100 at 3, 4, 5, 5e transmission distance 100 m (distance between hub and node) number of cascade connections no restrictions if switching hubs are used. number of nodes 254 message length 552 bytes max. date length 540 bytes max. (except for fins header 10 byte and command header 2 byte.) number of buffer 8k byte protocol name fins/udp method fins/tcp method protocol used udp/ip tcp/ip the selection of udp/ip or tcp/ip is made from the fins/tcp tab by the web browser function. number of connections --- 2 port number 9600 (default) can be changed. 9600 (default) can be changed. protection no yes (specification of client ip addresses when unit is used as a server)
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 33 connecting to support software operating environment and system configuration the following system is required to operate the cx-programmer. ma ke sure your system provides the following conditions and has the necessary components. connecting methods using commercially available usb cable, connect the cx-programmer to the peripheral usb port on the cpu unit. host link connection can be made wi th rs-232c port to connect the pr ogramming device (cx-programmer). connecting cable use the following cable to connect the cp1e cpu unit to the computer running the support software. usb port rs-232c port for n/na-type cpu units note: connectable with cx-programmer ver.9.1 or higher only. * use the usb-serial conversion cable cs1w-cif31 togethe r to connect a plc to a personal computer's usb port. item description supported computer ibm pc/at or equivalent cd-rom or dvd-rom drive one or more supported operating systems windows 2000 (service pack 4 or higher), xp, vista, or 7 (except 64-bit edition) cpu pentium ii 333 mhz or faster ram 256 mb min. 512 mb or more recommended available hard disk space 600 mb min. display 800 x 600 svga min. plc and connection port usb port, rs-232c port, rs-422a/485 port or ethernet port port at unit port at computer network type (communications mode) model numbers length peripheral usb port (conforming to usb 2.0, b connector) usb port usb 2.0 (or 1.1) commercially available usb cable (a connector - b connector) less than 5 m port at unit port at computer communications mode connecting cable model length remarks rs-232c port or cp1w-cif01 (add this to the option board slot.) rs-232c port * host link (sysway) xw2z-200s-cv 2m with anti-static connectors xw2z-500s-cv 5m with anti-static connectors xw2z-200s-v 2m --- xw2z-500s-v 5m --- usb port a connector commercially available usb cable peripheral usb port (conforming to usb 2.0, b connector) b connector cp1e cpu unit cx-programmer
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 34 unit versions unit versions and programming devices the following tables show the relationship bet ween unit versions and cx -programmer versions. unit versions and programming devices * a programming console cannot be used. units model numbers unit version cp1e cpu units cp1e-e @@ d @ - @ cp1e-n @@ d @ - @ cp1e-na @@ d @ - @ unit version 1. @ cpu unit functions required programming device * cx-programmer micro plc edition cx-programmer cx- programmer for cp1e ver.8.1 or lower ver.8.2 ver.9.03 or higher ver.8.1 or lower ver.8.2 ver.9.0 ver.9.03 or higher ver.1.0 cp1e-e10d @ - @ cp1e- @ 14d @ - @ cp1e-n60d @ - @ cp1e-na20d @ - @ unit version 1. @ functions not support. not support. yes supports smart input function. not support. not support. not support. yes supports smart input function. not support. cp1e-e20/30/40d @ -a cp1e-n20/30/40d @ - @ unit version 1. @ functions not support. yes does not support smart input function. yes supports smart input function. not support. yes does not support smart input function. yes supports smart input function. yes supports smart input function. yes supports smart input function.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 35 programming instructions sequence input instructions sequence output instructions sequence output instructions timer and counter instructions comparison instructions data movement instructions instruction mnemonic load ld load not ld not and and and not and not or or or not or not and load and ld or load or ld not not condition on up condition off down instruction mnemonic output out output not out not keep keep differentiate up difu differentiate down difd set set reset rset multiple bit set seta multiple bit reset rsta single bit set setb single bit reset rstb instruction mnemonic end end no operation nop interlock il interlock clear ilc multi-interlock differentiation hold milh multi-interlock differentiation release milr multi-interlock clear milc jump jmp jump end jme conditional jump cjp for loop for break loop break next loop next instruction mnemonic timer tim timx counter cnt cntx high-speed timer timh timhx one-ms timer tmhh tmhhx accumulative timer ttim ttimx long timer timl timlx reversible counter cntr cntrx reset timer/counter cnr cnrx instruction mnemonic input comparison instructions (unsigned) ld,and,or+= ld,and,or+<> ld,and,or+< ld,and,or+<= ld,and,or+> ld,and,or+>= input comparison instructions (double, unsigned) ld,and,or+=+l ld,and,or+<>+l ld,and,or+<+l ld,and,or+<=+l ld,and,or+>+l ld,and,or+>=+l input comparison instructions (signed) ld,and,or+=+s ld,and,or+<>+s ld,and,or+<+s ld,and,or+<=+s ld,and,or+>+s ld,and,or+>=+s input comparison instructions (double, signed) ld,and,or+=+sl ld,and,or+<>+sl ld,and,or+<+sl ld,and,or+<=+sl ld,and,or+>+sl ld,and,or+>=+sl time comparison instructions =dt <>dt
dt >=dt compare cmp double compare cmpl signed binary compare cps double signed binary compare cpsl table compare tcmp unsigned block compare bcmp area range compare zcp double area range compare zcpl instruction mnemonic move mov double move movl move not mvn move bit movb move digit movd multiple bit transfer xfrb block transfer xfer block set bset data exchange xchg single word distribute dist data collect coll
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 36 data shift instructions increment/decrement instructions symbol math instructions conversion instructions logic instructions special math instructions floating-point math instructions table data processing instructions data control instructions instruction mnemonic shift register sft reversible shift register sftr word shift wsft arithmetic shift left asl arithmetic shift right asr rotate left rol rotate right ror one digit shift left sld one digit shift right srd shift n-bits left nasl double shift n-bits left nsll shift n-bits right nasr double shift n-bits right nsrl instruction mnemonic increment binary ++ double increment binary ++l decrement binary -- double decrement binary --l increment bcd ++b double increment bcd ++bl decrement bcd --b double decrement bcd --bl instruction mnemonic signed binary add without carry + double signed binary add without carry +l signed binary add with carry +c double signed binary add with carry +cl bcd add without carry +b double bcd add without carry +bl bcd add with carry +bc double bcd add with carry +bcl signed binary subtract without carry - double signed binary subtract without carry -l signed binary subtract with carry -c double signed binary subtract with carry -cl bcd subtract without carry -b double bcd subtract without carry -bl bcd subtract with carry -bc double bcd subtract with carry -bcl signed binary multiply * double signed binary multiply * l bcd multiply * b double bcd multiply * bl signed binary divide / double signed binary divide /l bcd divide /b double bcd divide /bl instruction mnemonic bcd-to-binary bin double bcd-to-double binary binl binary-to-bcd bcd double binary-to-double bcd bcdl 2?s complement neg data decoder mlpx data encoder dmpx ascii convert asc ascii to hex hex instruction mnemonic logical and andw double logical and andl logical or orw double logical or orwl exclusive or xorw double exclusive or xorl complement com double complement coml instruction mnemonic arithmetic process apr bit counter bcnt instruction mnemonic floating to 16-bit fix floating to 32-bit fixl 16-bit to floating flt 32-bit to floating fltl floating-point add +f floating-point subtract -f floating-point divide /f floating-point multiply * f floating symbol comparison ld, and, or+=f ld, and, or+<>f ld, and, or+f ld, and, or+>=f floating- point to ascii fstr ascii to floating-point fval instruction mnemonic swap bytes swap frame checksum fcs instruction mnemonic pid control with autotuning pidat time-proportional output tpo scaling scl scaling 2 scl2 scaling 3 scl3 average avg
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 37 subroutine instructions interrupt control instructions high-speed counter and pulse output instructions step instructions i/o unit instructions serial communications instructions clock instructions failure diagnosis instructions other instructions instruction mnemonic subroutine call sbs subroutine entry sbn subroutine return ret instruction mnemonic set interrupt mask msks clear interrupt cli disable interrupts di enable interrupts ei instruction mnemonic mode control ini high-speed counter pv read prv comparison table load ctbl speed output sped set pulses puls pulse output pls2 acceleration control acc origin search org pulse with variable duty factor pwm instruction mnemonic step define step step start snxt instruction mnemonic i/o refresh iorf 7-segment decoder sdec digital switch input dsw matrix input mtr 7-segment display output 7seg instruction mnemonic transmit txd receive rxd instruction mnemonic calendar add cadd calendar subtract csub clock adjustment date instruction mnemonic failure alarm fal severe failure alarm fals instruction mnemonic set carry stc clear carry clc extend maximum cycle time wdt
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 38 dimensions (unit: mm) cp1e cpu unit cpu units with 10 i/o points cpu units with 14 or 20 i/o points cpu units with 30 i/o points cpu units with 20 i/o points and built-in analog 110 100 90 56 66 8 85 two, 4.5 dia. 85 8 90 100 86 76 110 two, 4.5 dia. 90 100 130 120 110 four, 4.5 dia. 85 8
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 39 cpu units with 40 i/o points cpu units with 60 i/o points 90 100 four, 4.5 dia. 150 140 110 85 8 110 100 90 185 195 8 85 four, 4.5 dia.
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 40 expansion i/o units and expansion units cp1w-8e @@ /cp1w-srt21 cp1w-20ed @ /cp1w-16e @@ /cp1w-ad041/cp1w-da021/cp1w-da041/cp1w-mad11/cp1w-ts @@@ cp1w-40ed @ /cp1w-32e @@ 50 66 56 0.2 90 100 0.2 5 8 5 two, 4.5 dia. 5 50 86 76 0.2 90 100 0.2 5 8 two, 4.5 dia. four, 4.5 dia. 8 50 90100110 140 150
cp1e-e @@d @ - @ cp1e-n @@ d @ - @/ na20d @ - @ 41 related manuals manual name cat. no. model numbers application contents sysmac cp series cp1e cpu unit hardware manual w479 cp1e-e @@d @ - @ cp1e-n @@d @ - @ cp1e-na @@ d @ - @ to learn the hardware specifications of the cp1e plcs describes the following information for cp1e plcs. ? overview and features ? basic system configuration ? part names and functions ? installation and settings ? troubleshooting use this manual together with the cp1e cpu unit software manual (cat. no. w480) and cp1e cpu unit instructions reference manual (cat. no. w483). sysmac cp series cp1e cpu unit software manual w480 cp1e-e @@d @ - @ cp1e-n @@d @ - @ cp1e-na @@ d @ - @ to learn the software specifications of the cp1e describes the following information for cp1e plcs. ? cpu unit operation ? internal memory ? programming ? settings ? cpu unit built-in functions ? interrupts ? high-speed counter inputs ? pulse outputs ? serial communications ? analog i/o function ? other functions use this manual together with the cp1e cpu unit hardware manual (cat. no. w479) and cp1e cpu unit instructions reference manual (cat. no. w483). sysmac cp series cp1e cpu unit instructions reference manual w483 cp1e-e @@d @ - @ cp1e-n @@d @ - @ cp1e-na @@ d @ - @ to lea rn progr amming instructions in detail describes each programming instruction in detail. when programming, use this manual together with the cp1e cpu unit hardware manual (cat. no. w479) and cp1e cpu unit software manual (cat. no. w480). cs/cj/cp/nsj series communications commands reference manual w342 cs1g/h-cpu @@h cs1g/h-cpu @@ -v1 cs1d-cpu @@h cs1d-cpu @@s cs1w-scu @@ -v1 cs1w-scb @@ -v1 cj1g/h-cpu @@ h cj1g-cpu @@ p cj1m-cpu @@ cj1g-cpu @@ cj1w-scu @@-v1 to learn communications commands for cs/cj/cp/nsj-series controllers in detail describes 1) c-mode commands and 2) fins commands in detail. read this manual for details on c-mode and fins commands addressed to cpu units. note: this manual describes commands addressed to cpu units. it does not cover commands addressed to other units or ports (e.g., serial communications ports on cpu units, communications ports on serial communications units/boards, and other communications units). sysmac cp series cp1l/cp1e cpu unit introduction manual w461 cp1l-l10d @ - @ cp1l-l14d @ - @ cp1l-l20d @ - @ cp1l-m30d @ - @ cp1l-m40d @ - @ cp1l-m60d @ - @ cp1e-e @@d @ - @ cp1e-n @@d @ - @ cp1e-na @@ d @ - @ to learn th e basic setup methods of the cp1l/cp1e plcs describes the following information for cp1l/cp1e plcs. ? basic configuration and component names ? mounting and wiring ? programming, data transfer, and debugging using the cx-programmer ? application program examples
memo 42
read and understand this catalog please read and understand this catalog before purchasing the pr oduct. please consult your omron representative if you have any questions or comments. warranty and limitations of liability warranty omron's exclusive warranty is that the pr oducts are free from defects in material s and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, expr ess or implied, regarding non-infringement, merchantability, or fitness for particular p urpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the products will suitably meet the requirements of their intended use. om ron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indire ct, or consequential damages, loss of profits or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, negligence, or strict liability. in no event shall the responsibility of omron for any act exceed the individual price of the product on which liability is asse rted. in no event shall omron be responsible for warr anty, repair, or other claims regarding the products unless omron's analysis confirms that the products we re properly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the product in the customer's applic ation or use of the product. take all necessary steps to determine the suitability of the pro duct for the systems, machines, and equipment with which it wil l be used. know and observe all prohibitions of use applicable to this product. never use the product for an application involvin g serious risk to life or property without ensuring that the system as a whole has been desi gned to address the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or system. programmable products omron shall not be responsible for the user's programming of a programmable product, or any consequence thereof. disclaimers change in specifications product specifications and accessories may be changed at any time based on improvements and other reasons. consult with your omron representative at any time to confir m actual specifications of purchased product. dimensions and weights dimensions and weights are nominal and are not to be used fo r manufacturing purposes, even when tolerances are shown. performance data performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omron's test conditi ons, and the users must correlate it to actual application requirements. actual performance is subject to the omron warranty and limitations of liability.
authorized distributor: in the interest of product improvement, specifications are subject to change without notice. cat. no. p061-e1-06 ? omron corporation 2009 all rights reserved. omron corporation industrial automation company omron electronics llc one commerce drive schaumburg, il 60173-5302 u.s.a. tel: (1) 847-843-7900/fax: (1) 847-843-7787 regional headquarters omron europe b.v. wegalaan 67-69-2132 jd hoofddorp the netherlands tel: (31)2356-81-300/fax: (31)2356-81-388 contact: www.ia.omron.com tokyo, japan omron asia pacific pte. ltd. no. 438a alexandra road # 05-05/08 (lobby 2), alexandra technopark, singapore 119967 tel: (65) 6835-3011/fax: (65) 6835-2711 omron (china) co., ltd. room 2211, bank of china tower, 200 yin cheng zhong road, pudong new area, shanghai, 200120, china csm_7_1_0311 tel: (86) 21-5037-2222/fax: (86) 21-5037-2200 0910 (0309) note: do not use this document to operate the unit.


▲Up To Search▲   

 
Price & Availability of CP1W-BAT01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X